A boiler GC number is a seven-digit reference that identifies the exact make and model of a gas appliance in the UK. You will usually find it on the boiler's data badge, in the user or installation manual, or on the Benchmark commissioning checklist left by the installer. Once you have it, you or your engineer can match spare parts to your boiler with confidence instead of guessing from the model name on the front panel.
This guide explains what the GC number is, where to look for it, how it differs from the model name, serial number and part number, and which parts need a Gas Safe registered engineer to fit them.
What is a boiler GC number?
GC stands for Gas Council, the body the numbering system dates back to. Gas appliances approved for sale in the UK are given one. The number is normally seven digits long and is often printed with hyphens, for example in the pattern 12-345-67 (an illustration only, not a real boiler).
The reason it matters is simple: manufacturers often sell several versions of a boiler under very similar names. Two boilers can share a range name and output but use different fans, gas valves, circuit boards or expansion vessels. The GC number pins down the exact appliance, so parts lists and spares finders can show only the components that fit it.
Where to find the GC number on your boiler
You do not need to take anything apart to find it. Start with these places, in this order:
- The data badge or rating label. This is a sticker or plate on the boiler itself. Depending on the make, it may be on the underside of the boiler, behind a drop-down flap or door over the controls, or on the side of the casing. If the badge is only visible with the front casing removed, stop there and ask your engineer for the number: the casing of a gas boiler should only be removed by a Gas Safe registered engineer.
- The user manual or installation manual. The GC number is usually printed on the front cover or in the technical data section.
- The Benchmark commissioning checklist. Most installers complete this when the boiler is fitted. It records the make, model and GC number, and is often at the back of the installation manual.
- Service records and engineer paperwork. A previous service sheet, landlord gas safety record or repair invoice will often list it.
If the label has faded or been painted over, the model name and serial number together are usually enough for a manufacturer or engineer to identify the appliance.
GC number, model name or part number: which do you need?
There are four different references you may come across, and each does a different job:
| Reference | What it identifies | Where you see it |
|---|---|---|
| Model name | The boiler range and output, for marketing | Front panel, brochure |
| GC number | The exact approved appliance | Data badge, manuals, Benchmark checklist |
| Serial number | That single boiler, including when it was made | Data badge |
| Manufacturer part number | One specific component | Parts list, engineer's quote, the old part's label |
The GC number tells you which parts list to use. The part number tells you which item on that list you need. Occasionally a manufacturer changes a component part-way through production, in which case the parts list will say which serial number range each version fits. That is why engineers sometimes ask for the serial number as well.
How to match a spare part to your boiler
The most reliable way to order the right part is to work from the manufacturer part number. In practice this usually comes from one of three places:
- Your engineer's diagnosis or quote. When an engineer finds a fault, they will normally quote the part number from the manufacturer's parts list for your GC number.
- The old part. Many components carry the part number on a label or moulding. Your engineer can read this when the part is removed.
- The manufacturer's parts list. Look up your GC number with the boiler manufacturer and find the component in the exploded diagram.
At BHL, our boiler spares are listed with the manufacturer part number in the product title, so you can search our boiler spares range for that number directly. For example, the Baxi 8L expansion vessel is listed with Baxi part number 248024, and the Worcester Bosch 12L expansion vessel with part number 87161425050. If the number in the title matches the number on your engineer's quote, you have the right item.
If you are not sure, contact us with the GC number, the model name and the part number you have been given before ordering. It is much quicker to check first than to return a part.
Common boiler spare parts and what they do

These are some of the parts most often replaced on domestic gas boilers. Each example below is a part we stock, with its manufacturer part number in the title.
Expansion vessel
A sealed central heating system needs somewhere for water to go as it heats up and expands. The expansion vessel absorbs that extra volume. When a vessel loses its charge or fails, system pressure tends to rise sharply when the heating runs and drop again when it cools. Examples: Baxi 8L expansion vessel 248024 and Worcester Bosch 12L expansion vessel 87161425050.
Filling loop
The filling loop connects the mains cold water supply to the sealed heating circuit so the system can be topped up to the right pressure. Some are external hoses under the boiler, others are built in. Example: Glow-worm filling loop 2000802600.
Pressure gauge
The gauge on the front or underside of the boiler shows the system pressure. If it sticks or reads incorrectly, it can hide a pressure problem. Example: Baxi pressure gauge 248090.
Printed circuit board (PCB)
The PCB is the boiler's control board. It manages ignition, the fan, the pump and the heating and hot water demands. Example: Worcester Bosch PCB 87483002190.
Diverter (3 way) valve parts
On combination boilers the diverter valve sends hot water either to the radiators or to the taps. A worn diaphragm can stop it switching properly, which often shows up as lukewarm radiators while the hot water is on, or the reverse. Example: Baxi diaphragm for 3 way valve 248065. Actuator heads for diverter and zone valves are in our actuator valves range, and valve bodies and spares are under valves.
For flue parts, condensate traps, controls and other items, browse domestic boiler accessories or the wider boilers and accessories department. If you know the make, the brand pages for Baxi and Worcester Bosch are a quick way to narrow the list.
Which boiler parts must be fitted by a Gas Safe engineer?
Any work inside the casing of a gas boiler, and any work on its gas supply, must be carried out by a Gas Safe registered engineer. That covers almost every part listed above, including the expansion vessel, PCB, diverter valve, pressure relief valve, fan, gas valve, electrodes and heat exchanger. These jobs involve gas, combustion, electrics and pressurised water, and the boiler needs to be checked and tested before it is put back into service.
What you can safely do yourself is limited to what the boiler's user manual describes, such as reading the pressure gauge and topping up the system with the filling loop as the manual explains. Everything else is a job for your engineer. You can check that an engineer is registered, and which appliances they are qualified to work on, with the Gas Safe Register.
Many engineers are happy for customers to buy parts in advance once the fault has been diagnosed, but agree this with them first and give them the part number you plan to order.
Ordering boiler spares from BHL: FAQ
Can I order a boiler part using only the GC number?
The GC number tells you which boiler you have, but not which component has failed. You will also need the manufacturer part number, which your engineer can give you after diagnosing the fault.
My boiler label is missing. What now?
Check the manuals and the Benchmark checklist first. If those are missing too, your engineer can identify the boiler during a visit, and the manufacturer can usually help if you give them the model name and serial number.
Is a part from the same brand always compatible?
No. Parts that look similar can differ in size, connection, rating or software. Always match the manufacturer part number for your GC number rather than the brand or appearance.
Can I fit a filling loop or expansion vessel myself?
No. Replacing any component on a gas boiler is a job for a Gas Safe registered engineer. You can use the filling loop to top up pressure as your user manual describes, but replacing parts is engineer work.