Honeywell Resideo 2-Port Motorised Zone Valve, 2 Way Heating Control Valve, Motorised Diverter Valve, Central Heating Zone Control, Replacement Valve

In stock
£132.05

Honeywell Resideo 2-Port Motorised Zone Valve, 2 Way Heating Control Valve, Motorised Diverter Valve, Central Heating Zone Control, Replacement Valve

SKU W-K13305
Manufacturer part number
V4023PH22/U
EAN
5059087009876
£132.05
inc VAT£110.04 ex VAT
Lead time: 1-5 working days

Questions about this product? Chat with us

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Honeywell Resideo 2-Port Motorised Zone Valve, 2 Way Heating Control Valve, Motorised Diverter Valve, Central Heating Zone Control, Replacement Valve (Part no. W-K13305)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

Product Overview

The Honeywell Resideo 2-Port Motorised Zone Valve is a reliable 2 way heating control valve designed to regulate water flow to a heating zone or circuit. Commonly used in domestic central heating systems, it helps you control where heat is sent, improving comfort and energy efficiency. Ideal as a like-for-like replacement when an existing motorised valve fails or becomes unreliable.

Key Features

  • 2-port (2 way) zone control – helps isolate and control individual heating zones for better comfort and reduced wasted heat.
  • Motorised operation – automatically opens and closes flow to support consistent heating control without manual adjustment.
  • Suitable for replacement installations – designed for straightforward swap-outs when upgrading or repairing a central heating system.
  • Honeywell Resideo build quality – dependable performance for day-to-day heating and hot water control in busy homes.

Use Case / Application

Suitable for use in typical UK domestic and light commercial heating systems where motorised zoning is required. Common applications include:

  • Controlling a radiator zone such as upstairs or downstairs heating
  • Managing a separate heating circuit for an extension, conservatory or garage conversion
  • Supporting timed and thermostatically controlled heating schedules
  • Repairs and maintenance where a failed motorised valve is causing no-heat or constant-heat issues

Problem → Solution

Ideal for restoring reliable heating zone control when a worn or sticking motorised valve is causing poor temperature control, no flow, or heating running when it should be off.

Product Specifications

Manufacturer – Honeywell Resideo
Manufacturer Part Number (MPN) – V4023PH22/U
Product Type – 2-Port Motorised Zone Valve
Typical Applications / Use Cases – Central heating zone control, heating circuit isolation, replacement motorised heating valve

Why Buy from BHL

Honeywell Resideo is known for dependable heating controls used by installers across the UK, and this 2-port motorised zone valve is designed for reliable day-to-day zoning and system control. Order online from BHL, a specialist heating, plumbing and building supplies merchant trading online since 1998.

Reviews

Buying guide: Central Heating Valves

Central heating valves direct and control the flow of hot water from the boiler to the radiators and the hot water cylinder. This category covers motorised two-port zone valves, three-port mid-position and diverter valves, automatic bypass valves, replacement actuators and powerheads, and control packs that pair a valve with a thermostat or timer.

Motorised valves

  • Two-port zone valves: open or close one circuit, such as the heating or the hot water, so each zone can have its own time and temperature control.
  • Three-port mid-position valves: direct water to the heating, the hot water or, resting midway, both at once.
  • Three-port diverter valves: direct water to one circuit or the other, not both together.

Sizes include 22mm and 28mm compression, BSP threads and some 15mm versions. On many valves the actuator or powerhead can be changed without draining the system, and a manual lever opens the valve for filling and draining. Check the flow arrow on the body, and match a replacement head to the valve body.

Bypass valves

An automatic bypass valve opens as radiator and zone valves close, keeping a minimum flow through the boiler and limiting pressure build-up. Bypass valves fitted inside a boiler are boiler parts: work inside a gas boiler must only be carried out by a Gas Safe registered engineer.

Regulations and wiring

In England, Approved Document L expects controls wired so the boiler and pump switch off when neither heating nor hot water is needed; TRVs alone do not do this. A new heating system in a home of 150 square metres or more should have at least two heating zones. Wiring should be done by a competent person to the current wiring regulations.

For thermostats and programmers, see heating controls; for radiator valves, see thermostatic radiator valves.