Adey Mc1 Quick Test Kit

Adey Filters MC1 Quick Test Kit, Central Heating Inhibitor Water Test Kit, System Cleaner Test, Heating System Diagnostic Kit

In stock
£63.42
Skip to product information
Adey Mc1 Quick Test Kit
About product images

Product images

Some images represent a product range or show a complete installation for context. The size, finish and items included may vary depending on the option selected. Please check the product description and specifications to confirm what’s supplied, as other components or accessories pictured may be sold separately.

If you’re unsure, our team will be happy to help before you order.

Adey Filters MC1 Quick Test Kit, Central Heating Inhibitor Water Test Kit, System Cleaner Test, Heating System Diagnostic Kit

SKU W-608069
Manufacturer part number
CP1-03-00742
EAN
5060106370129
£63.42
inc VAT£52.85 ex VAT
Lead time: 1-5 working days

Questions about this product? Chat with us

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Adey Filters MC1 Quick Test Kit, Central Heating Inhibitor Water Test Kit, System Cleaner Test, Heating System Diagnostic Kit (Part no. W-608069)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

The Adey Filters MC1 Quick Test Kit is designed to provide a quick, practical on-site check of central heating system water treatment, helping you verify whether protective inhibitor levels are within an acceptable range. Ideal for routine servicing and maintenance, it supports better system efficiency and helps reduce the risk of corrosion, limescale and sludge build-up when used as part of a regular water quality regime.

Product Features

  • Quick and convenient test method for heating system water treatment checks
  • Supports maintenance of correct inhibitor protection levels for improved system reliability
  • Helps identify when additional inhibitor top-up may be required
  • Suitable for use during servicing, commissioning and ongoing system care
  • Compact kit format for easy transport and on-site use

Product Specifications

  • Manufacturer – Adey Filters
  • Manufacturer Part Number (MPN) – CP1-03-00742
  • EAN / Barcode – 5060106370129
  • Product Type – Central heating inhibitor water test kit
  • Typical Applications / Use Cases – Testing central heating system water during servicing/maintenance to confirm inhibitor protection and support ongoing system care

Adey Filters is known for practical solutions that help protect and maintain central heating systems. Buy the Adey Filters MC1 Quick Test Kit online from BHL for competitive pricing and free* & fast UK delivery. Order today to keep your system checks simple and reliable. *see our terms

Reviews

Buying guide: Water Treatment

Water treatment covers products that protect heating systems, boilers and appliances from corrosion, sludge and limescale. The range includes magnetic system filters, central heating inhibitors, cleaners, leak sealers and noise reducers, flushing equipment, water test kits, limescale reducers and water softeners.

Central heating systems

BS 7593 is the code of practice for water treatment in domestic heating systems. When a new boiler is fitted, the system should be chemically cleaned and flushed with fresh water, then dosed with an inhibitor that protects against corrosion and scale, and an in-line filter fitted. Check the inhibitor level regularly with a test kit and top up when needed. Leak sealers and noise reducers treat specific faults rather than replacing an inhibitor. Match a filter to the pipe size, commonly 22mm or 15mm.

Limescale and hard water

In England, building regulations guidance recommends treating the water feeding combination boilers and water heaters where hardness is above 200 parts per million, to slow the build-up of limescale. Options include electrolytic or magnetic scale reducers, polyphosphate dosing, scale inhibitors and water softeners.

Water softeners

Ion exchange softeners take hardness out of the water and are topped up with salt. Keep an unsoftened cold tap for drinking, usually at the kitchen sink, and do not use softened water to make up baby feeds. Fit a bypass valve so the softener can be isolated. Softeners and other fittings on the mains must be suitable under the Water Supply (Water Fittings) Regulations 1999.