Worcester Bosch 8736500004 Zone Valve, Heating Zone Control Valve, 2 Port Motorised Valve Replacement, Central Heating Diverter Valve

In stock
£94.68

Worcester Bosch 8736500004 Zone Valve, Heating Zone Control Valve, 2 Port Motorised Valve Replacement, Central Heating Diverter Valve

SKU W-417514
Manufacturer part number
8736500004
EAN
4051516741952
£94.68
inc VAT£78.90 ex VAT
Lead time: 1-5 working days

Questions about this product? Chat with us

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Worcester Bosch 8736500004 Zone Valve, Heating Zone Control Valve, 2 Port Motorised Valve Replacement, Central Heating Diverter Valve (Part no. W-417514)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

Product Overview

The Worcester Bosch 8736500004 zone valve is a central heating control component designed to regulate water flow to a specific heating zone. It helps your system direct heat where it is needed, improving comfort and aiding efficient operation. Ideal for maintaining reliable zoning control and restoring performance when replacing a faulty valve.

Key Features

  • Accurate zone control – helps manage hot water flow to individual heating zones for better comfort and efficiency.
  • Reliable replacement part – ideal for swapping out a worn or sticking valve to restore proper heating operation.
  • Designed for Worcester Bosch systems – suitable for compatible installations where MPN 8736500004 is specified.
  • Helps prevent heating imbalance – supports consistent radiator performance by controlling flow to the correct circuit.
  • Genuine part identification – supplied to match the manufacturer reference, helping reduce compatibility guesswork.

Use Case / Application

Designed for use in domestic and light commercial central heating systems that use zoned heating control. Typically installed within airing cupboards, utility rooms, plant rooms, or near the boiler and pipework manifold to control flow to:

  • Upstairs and downstairs heating zones
  • Separate radiator circuits and timed heating schedules
  • Multi-zone properties needing independent temperature control

Problem → Solution

Ideal for homes with heating zones that are not warming correctly or are overheating, where replacing the zone control valve helps restore correct flow control and dependable heating performance.

Product Specifications

  • Manufacturer – Worcester Bosch
  • Manufacturer Part Number (MPN) – 8736500004
  • EAN / Barcode – 4051516741952
  • Product Type – Zone Valve
  • Typical Applications / Use Cases – Zoned central heating systems, heating circuit flow control, replacement during servicing or repair

Why Buy from BHL

Worcester Bosch products are trusted across the UK for quality and long-term reliability in home heating systems, and this zone valve is a dependable choice when you need a correct like-for-like replacement. Buy online from BHL for competitive pricing, free* and fast UK delivery, and genuine parts delivered with care from UK warehouses. BHL are a specialist online merchant, trusted by thousands of satisfied customers online since 1998 with thousands of 5 star reviews. Order the Worcester Bosch 8736500004 today for a smooth repair and restored heating control.

*see our terms

Reviews

Buying guide: Central Heating Valves

Central heating valves direct and control the flow of hot water from the boiler to the radiators and the hot water cylinder. This category covers motorised two-port zone valves, three-port mid-position and diverter valves, automatic bypass valves, replacement actuators and powerheads, and control packs that pair a valve with a thermostat or timer.

Motorised valves

  • Two-port zone valves: open or close one circuit, such as the heating or the hot water, so each zone can have its own time and temperature control.
  • Three-port mid-position valves: direct water to the heating, the hot water or, resting midway, both at once.
  • Three-port diverter valves: direct water to one circuit or the other, not both together.

Sizes include 22mm and 28mm compression, BSP threads and some 15mm versions. On many valves the actuator or powerhead can be changed without draining the system, and a manual lever opens the valve for filling and draining. Check the flow arrow on the body, and match a replacement head to the valve body.

Bypass valves

An automatic bypass valve opens as radiator and zone valves close, keeping a minimum flow through the boiler and limiting pressure build-up. Bypass valves fitted inside a boiler are boiler parts: work inside a gas boiler must only be carried out by a Gas Safe registered engineer.

Regulations and wiring

In England, Approved Document L expects controls wired so the boiler and pump switch off when neither heating nor hot water is needed; TRVs alone do not do this. A new heating system in a home of 150 square metres or more should have at least two heating zones. Wiring should be done by a competent person to the current wiring regulations.

For thermostats and programmers, see heating controls; for radiator valves, see thermostatic radiator valves.

Shop all Central Heating Valves

Related products

Customers also bought