Danfoss Liquid Receiver 3 4L, Refrigeration Receiver Tank, Liquid Refrigerant Storage Vessel, HVACR Spare Part, Replacement Component

In stock
£373.06

Danfoss Liquid Receiver 3 4L, Refrigeration Receiver Tank, Liquid Refrigerant Storage Vessel, HVACR Spare Part, Replacement Component

SKU W-683976
Manufacturer part number
118U3475
£373.06
inc VAT£310.88 ex VAT
Lead time: 1-5 working days

Questions about this product? Chat with us

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Danfoss Liquid Receiver 3 4L, Refrigeration Receiver Tank, Liquid Refrigerant Storage Vessel, HVACR Spare Part, Replacement Component (Part no. W-683976)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

Product Overview

The Danfoss Liquid Receiver 3 4L is a refrigeration liquid receiver designed to store liquid refrigerant and help maintain stable system operation. Suitable for HVACR and refrigeration pipework setups where a reliable receiver vessel supports smoother running and serviceability. A genuine replacement component specified by Danfoss for dependable performance.

Key Features

  • 4L receiver capacity – helps manage refrigerant volume and supports more stable system operation.
  • Designed for liquid refrigerant storage – assists with maintaining correct liquid feed conditions within the refrigeration circuit.
  • Danfoss manufactured component – built for consistent quality and dependable fit in compatible systems.
  • Ideal replacement part – simplifies maintenance by matching the original specification via the MPN.

Use Case / Application

Designed for use in refrigeration and HVACR systems where a liquid receiver vessel is required to store refrigerant and support system control. Commonly installed within plant rooms, commercial refrigeration back-of-house areas, cold rooms, chilled display systems, and packaged HVACR equipment. Suitable for service engineers carrying out repairs, upgrades, or like-for-like replacement using the manufacturer part number.

Problem → Solution

Ideal for systems needing controlled liquid refrigerant storage to help improve stability and make servicing and maintenance more straightforward.

Product Specifications

• Manufacturer – Danfoss
• Manufacturer Part Number (MPN) – 118U3475
• Dimensions / Size – 4L capacity
• Product Type – Liquid Receiver (Refrigeration Receiver Tank)
• Typical Applications / Use Cases – Refrigeration and HVACR systems requiring a liquid refrigerant storage receiver vessel

Why Buy from BHL

Danfoss is a trusted manufacturer of refrigeration and heating system components, specified by professionals for reliable performance. Buy the Danfoss Liquid Receiver 3 4L Part Number 118U3475 online from BHL for competitive pricing and free and fast UK delivery with care from UK warehouses. BHL are a specialist online merchant, trusted by thousands of satisfied customers online since 1998, with thousands of 5 star reviews. Order today for genuine parts and a smooth, professional purchase experience. Free* delivery available on eligible orders, see our terms

Reviews

Buying guide: Refrigeration

This category holds replacement parts for refrigeration and cooling equipment: hermetic, semi-hermetic and scroll compressors, condenser and evaporator fan motors, refrigerant oils, refrigerant cans and cylinders, adaptors, seals and fan controls.

Matching a compressor

  • Refrigerant: each compressor is built for particular refrigerants, such as R134a, R404A, R407C, R290 or R600a, so match the refrigerant already in the system.
  • Application range: compressors are rated LBP, MBP or HBP (low, medium or high back pressure) for the evaporating temperature they work at. LBP covers the coldest range, as in freezers, and HBP the warmest; check the range against what the system was designed for.
  • Electrical supply: check single phase 230V or three phase 400V, and the frequency; some models are wound for supplies outside the UK.
  • Capacity and connections: match the cooling capacity at the system's operating conditions, and choose a valved version if the system needs service valves.

Oils and refrigerants

Use the oil type and grade the compressor maker specifies. Synthetic polyolester (POE) oil is the usual choice for HFC refrigerants such as R134a, R404A and R407C. Hydrocarbon refrigerants such as R290 and R600a are flammable and need careful handling, so only technicians trained in the safe use of flammable refrigerants should open these systems.

Regulations

In Great Britain, anyone who installs, services or maintains, leak checks, recovers refrigerant from or decommissions stationary refrigeration, air conditioning or heat pump equipment containing F gas must hold the right F gas qualification, and the certificate category depends on the size of the system.

For valves, see valves; for copper pipe and fittings, see pipe systems and fittings.