Danfoss T2 Flare/Flare Internal Equ - R407f

Danfoss T2 Flare Internal Equalised Expansion Valve for R407F, TE2 TXV, thermostatic expansion valve, refrigerant metering valve

In stock
£60.84
Skip to product information
Danfoss T2 Flare/Flare Internal Equ - R407f
About product images

Product images

Some images represent a product range or show a complete installation for context. The size, finish and items included may vary depending on the option selected. Please check the product description and specifications to confirm what’s supplied, as other components or accessories pictured may be sold separately.

If you’re unsure, our team will be happy to help before you order.

Danfoss T2 Flare Internal Equalised Expansion Valve for R407F, TE2 TXV, thermostatic expansion valve, refrigerant metering valve

SKU W-623132
Manufacturer part number
068Z3715
EAN
5702428843454
£60.84
inc VAT£50.70 ex VAT
Express delivery: allow 1 to 2 working daysExpress

Questions about this product? Chat with us

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Danfoss T2 Flare Internal Equalised Expansion Valve for R407F, TE2 TXV, thermostatic expansion valve, refrigerant metering valve (Part no. W-623132)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Specifications

ColourWhite

Description

Danfoss T2 FLARE FLARE INT EQU is a thermostatic expansion valve designed to meter refrigerant accurately and help maintain stable evaporator superheat in refrigeration and air conditioning systems. This T2 valve configuration uses flare connections and an internal equalisation arrangement, and is specified for use with R407F refrigerant.

Product Features

  • Thermostatic expansion valve for precise refrigerant flow control
  • Flare to flare connections for serviceable installation
  • Internal equalised design to suit appropriate evaporator and system layouts
  • Specified for systems using R407F refrigerant
  • Suitable for refrigeration and air conditioning applications requiring stable superheat control

Product Specifications

  • Manufacturer Danfoss
  • Manufacturer Part Number (MPN) 068Z3715
  • EAN Barcode 5702428843454
  • Product Type Thermostatic Expansion Valve TE2 TXV
  • Typical Applications Use Cases Refrigeration and air conditioning systems, evaporator refrigerant metering, superheat control, R407F installations
  • Technical Specifications T2 flare flare, internal equalised, refrigerant R407F
Danfoss is a leading global manufacturer of refrigeration and HVAC components, trusted for quality and reliability. Buy online from BHL for competitive pricing and free* and fast UK delivery on this specific part. Order Danfoss 068Z3715 today for a dependable replacement. *see our terms

Reviews

Buying guide: Heating Controls

Heating controls switch a central heating system on and off and hold rooms and hot water at the right temperature. This category covers room thermostats, programmers and time switches, programmable and smart thermostats, wireless thermostats with boiler receivers, smart radiator thermostats, motorised zone and diverter valves, valve actuators and wiring parts.

Types of control

  • Programmers and time switches: set when the heating and hot water come on.
  • Room thermostats: switch the heating off when the room reaches the set temperature. Programmable room thermostats combine time and temperature control in one unit.
  • Wireless and smart controls: a wireless thermostat talks to a receiver wired at the boiler. Smart thermostats add app control, and some learn your routine and start the boiler at the right time to reach the set temperature.
  • Motorised valves: on systems with a hot water cylinder, either one 3-port valve or a pair of 2-port valves directs heated water to the radiators, the cylinder or both. Match the pipe size and valve type when replacing one.

Regulations

In England, Approved Document L sets minimum controls when a gas or oil boiler is replaced: a programmer, a room thermostat, thermostatic control in each room (usually TRVs on every radiator except in the room with the main thermostat) and boiler interlock, so the boiler and pump switch off when nothing calls for heat. Systems with a cylinder also need separate hot water timing and a cylinder thermostat. A replacement gas combi boiler also needs one extra measure, such as weather or load compensation, flue gas heat recovery or a smart thermostat with automation and optimisation.

Mains wiring to controls and valves is electrical work, and some electrical work in homes is notifiable under Part P. For radiator valves, see thermostatic radiator valves, or browse radiators.

Shop all Heating Controls

Related products