Danfoss Ts 2 Flare Internal Equ Range N

Danfoss TS 2 Flare Internal Equaliser Expansion Valve Range N, thermostatic expansion valve, TXV, refrigeration valve, cooling control valve

In stock
£60.84
Skip to product information
Danfoss Ts 2 Flare Internal Equ Range N
About product images

Product images

Some images represent a product range or show a complete installation for context. The size, finish and items included may vary depending on the option selected. Please check the product description and specifications to confirm what’s supplied, as other components or accessories pictured may be sold separately.

If you’re unsure, our team will be happy to help before you order.

Danfoss TS 2 Flare Internal Equaliser Expansion Valve Range N, thermostatic expansion valve, TXV, refrigeration valve, cooling control valve

SKU W-675087
Manufacturer part number
068Z3400
EAN
5702422125280
£60.84
inc VAT£50.70 ex VAT
Express delivery: allow 1 to 2 working daysExpress

Questions about this product? Chat with us

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Danfoss TS 2 Flare Internal Equaliser Expansion Valve Range N, thermostatic expansion valve, TXV, refrigeration valve, cooling control valve (Part no. W-675087)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

The Danfoss TS 2 Flare Internal Equaliser Expansion Valve Range N is designed for accurate and dependable refrigerant flow control in compatible refrigeration and air conditioning systems. Built to support stable system performance, it helps maintain correct superheat control where an internal equaliser arrangement is specified.

Product Features

  • Thermostatic expansion valve design for controlled refrigerant metering
  • Flare connection type for straightforward installation in suitable pipework
  • Internal equaliser configuration (where specified by the system design)
  • Suited to Danfoss TS 2 Range N applications
  • Ideal for servicing, maintenance and like-for-like replacement

Product Specifications

  • Manufacturer – Danfoss
  • Manufacturer Part Number (MPN) – 068Z3400
  • Manufacturer Range / Series – TS 2 Range N
  • EAN / Barcode – 5702422125280
  • Product Type – Thermostatic Expansion Valve (TXV), Flare, Internal Equaliser
  • Typical Applications / Use Cases – Refrigeration systems, cooling equipment and air conditioning applications requiring a TS 2 internal equaliser flare expansion valve

Danfoss is a leading manufacturer of refrigeration and cooling controls, trusted for quality and long service life. Buy online from BHL for competitive pricing and free* and fast UK delivery on this specific part. Order Danfoss 068Z3400 today for a reliable replacement. *see our terms

Reviews

Buying guide: Heating Controls

Heating controls switch a central heating system on and off and hold rooms and hot water at the right temperature. This category covers room thermostats, programmers and time switches, programmable and smart thermostats, wireless thermostats with boiler receivers, smart radiator thermostats, motorised zone and diverter valves, valve actuators and wiring parts.

Types of control

  • Programmers and time switches: set when the heating and hot water come on.
  • Room thermostats: switch the heating off when the room reaches the set temperature. Programmable room thermostats combine time and temperature control in one unit.
  • Wireless and smart controls: a wireless thermostat talks to a receiver wired at the boiler. Smart thermostats add app control, and some learn your routine and start the boiler at the right time to reach the set temperature.
  • Motorised valves: on systems with a hot water cylinder, either one 3-port valve or a pair of 2-port valves directs heated water to the radiators, the cylinder or both. Match the pipe size and valve type when replacing one.

Regulations

In England, Approved Document L sets minimum controls when a gas or oil boiler is replaced: a programmer, a room thermostat, thermostatic control in each room (usually TRVs on every radiator except in the room with the main thermostat) and boiler interlock, so the boiler and pump switch off when nothing calls for heat. Systems with a cylinder also need separate hot water timing and a cylinder thermostat. A replacement gas combi boiler also needs one extra measure, such as weather or load compensation, flue gas heat recovery or a smart thermostat with automation and optimisation.

Mains wiring to controls and valves is electrical work, and some electrical work in homes is notifiable under Part P. For radiator valves, see thermostatic radiator valves, or browse radiators.

Shop all Heating Controls

Related products

Customers also bought