Evinox 3 Way Modusat Diverter Valve, 3-Port Diverting Valve, Heating Control Valve, Replacement Modusat Valve, Flow Direction Valve

In stock
£244.73

Evinox 3 Way Modusat Diverter Valve, 3-Port Diverting Valve, Heating Control Valve, Replacement Modusat Valve, Flow Direction Valve

SKU W-621266
Manufacturer part number
MFR_00943
£244.73
inc VAT£203.94 ex VAT
Lead time: 1-5 working days

Questions about this product? Chat with us

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Evinox 3 Way Modusat Diverter Valve, 3-Port Diverting Valve, Heating Control Valve, Replacement Modusat Valve, Flow Direction Valve (Part no. W-621266)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

Product Overview

The Evinox MFR_00943 is a 3 way Modusat diverter valve designed to switch or divert water flow between circuits within a heating or hot water system. Ideal for maintenance and repairs, it helps restore correct flow control, improving system performance and reliability.

Key Features

  • 3-way diverting action – directs flow to the required circuit for dependable heating and hot water control.
  • Designed as a like-for-like replacement – ideal for servicing and repairs where the original valve needs changing.
  • Helps reduce performance issues – supports correct system operation when poor circulation or incorrect flow direction is the problem.
  • Quality Evinox component – built for reliable operation in demanding plumbing and heating environments.

Use Case / Application

Suitable for use in domestic and light commercial plumbing and heating installations where a 3 way valve is required to divert water between circuits. Commonly used in plant rooms, airing cupboards, utility spaces and boiler or cylinder installations to manage flow between heating zones, hot water circuits, or mixed system demands.

Problem to Solution

Ideal for fixing systems where water is not diverting correctly between heating and hot water circuits, helping restore proper control and consistent performance.

Product Specifications

  • Manufacturer – Evinox
  • Manufacturer Part Number (MPN) – MFR_00943
  • Product Type – 3 Way Modusat Diverter Valve

Why Buy from BHL

Evinox manufactures dependable components used across plumbing and heating systems, with parts designed for consistent control and long service life. Order the Evinox 3 Way Modusat Diverter Valve (MFR_00943) from BHL for competitive pricing and genuine parts. BHL is a specialist online merchant, trusted by thousands of satisfied customers online since 1998 with thousands of 5 star reviews. Buy online today for free* and fast UK delivery, dispatched with care from UK warehouses. *see our terms

Reviews

Buying guide: Central Heating Valves

Central heating valves direct and control the flow of hot water from the boiler to the radiators and the hot water cylinder. This category covers motorised two-port zone valves, three-port mid-position and diverter valves, automatic bypass valves, replacement actuators and powerheads, and control packs that pair a valve with a thermostat or timer.

Motorised valves

  • Two-port zone valves: open or close one circuit, such as the heating or the hot water, so each zone can have its own time and temperature control.
  • Three-port mid-position valves: direct water to the heating, the hot water or, resting midway, both at once.
  • Three-port diverter valves: direct water to one circuit or the other, not both together.

Sizes include 22mm and 28mm compression, BSP threads and some 15mm versions. On many valves the actuator or powerhead can be changed without draining the system, and a manual lever opens the valve for filling and draining. Check the flow arrow on the body, and match a replacement head to the valve body.

Bypass valves

An automatic bypass valve opens as radiator and zone valves close, keeping a minimum flow through the boiler and limiting pressure build-up. Bypass valves fitted inside a boiler are boiler parts: work inside a gas boiler must only be carried out by a Gas Safe registered engineer.

Regulations and wiring

In England, Approved Document L expects controls wired so the boiler and pump switch off when neither heating nor hot water is needed; TRVs alone do not do this. A new heating system in a home of 150 square metres or more should have at least two heating zones. Wiring should be done by a competent person to the current wiring regulations.

For thermostats and programmers, see heating controls; for radiator valves, see thermostatic radiator valves.