Heatmiser Underfloor Heating UH8RF-V2 8 Zone RF Wiring Centre, Underfloor Heating Control Hub, Wireless Thermostat Receiver, Multi Zone UFH Controller Part Number: UHRF-V2

Heatmiser Underfloor Heating UH8RF-V2 8 Zone RF Wiring Centre, Underfloor Heating Control Hub, Wireless Thermostat Receiver, Multi Zone UFH Controller

In stock
£151.44
Skip to product information
Heatmiser Underfloor Heating UH8RF-V2 8 Zone RF Wiring Centre, Underfloor Heating Control Hub, Wireless Thermostat Receiver, Multi Zone UFH Controller Part Number: UHRF-V2
About product images

Product images

Some images represent a product range or show a complete installation for context. The size, finish and items included may vary depending on the option selected. Please check the product description and specifications to confirm what’s supplied, as other components or accessories pictured may be sold separately.

If you’re unsure, our team will be happy to help before you order.

Heatmiser Underfloor Heating UH8RF-V2 8 Zone RF Wiring Centre, Underfloor Heating Control Hub, Wireless Thermostat Receiver, Multi Zone UFH Controller

SKU W-605538
Manufacturer part number
UHRF-V2
EAN
5060267970411
£151.44
inc VAT£126.20 ex VAT
Lead time: 1-5 working days

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Heatmiser Underfloor Heating UH8RF-V2 8 Zone RF Wiring Centre, Underfloor Heating Control Hub, Wireless Thermostat Receiver, Multi Zone UFH Controller (Part no. W-605538)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

Short Intro

The Heatmiser UH8RF-V2 is an 8 zone RF wiring centre designed for controlling multi-room underfloor heating systems from one central hub. It’s used to connect and manage multiple heating zones while working with compatible wireless (RF) thermostats. Ideal for cleaner installations, easier zoning and more efficient comfort control throughout the home.

Key Features

  • 8-zone control from one wiring centre – manage multiple rooms independently for better comfort and reduced energy waste.
  • RF (wireless) thermostat compatibility – helps minimise wiring runs, making installs and retrofits simpler and tidier.
  • Centralised underfloor heating connections – keeps wiring organised for faster fault-finding and easier maintenance.
  • Designed for multi-zone UFH systems – supports structured zoning, making it ideal for modern homes and extensions.

Use Case / Application

Suitable for use in domestic and light commercial underfloor heating installations where you need reliable multi-zone control. Common applications include:

  • Living rooms, kitchens and open-plan areas split into separate heating zones
  • Bedrooms and upstairs landings requiring independent temperature schedules
  • Home extensions, garden rooms and renovations where wireless control reduces disruption
  • Utility areas and bathrooms where consistent heat and zoning improve comfort

Problem → Solution

Ideal for anyone needing a neat, central way to control multiple underfloor heating zones without running excessive cabling—helping you achieve reliable room-by-room temperature control.

Product Specifications

• Manufacturer – Heatmiser Underfloor Heating
• Manufacturer Part Number (MPN) – UHRF-V2
• EAN / Barcode – 5060267970411
• Product Type – 8 Zone RF Wiring Centre / Underfloor Heating Control Hub
• Typical Applications / Use Cases – Multi-zone underfloor heating control; wireless thermostat (RF) zoning in domestic and light commercial properties
• Technical Specifications – 8 heating zones; RF (wireless) control compatibility

Why buy from BHL?

Heatmiser Underfloor Heating is known for dependable, installer-trusted heating controls that make zoning and comfort management straightforward. The UH8RF-V2 wiring centre is a practical choice for organising and controlling an 8-zone underfloor heating system with RF functionality. Buy online from BHL for competitive pricing, free* & fast UK delivery and genuine parts delivered with care from UK warehouses. BHL is a specialist online merchant, trusted by thousands of satisfied customers online since 1998 with thousands of 5 star reviews—order your UHRF-V2 today.
*see our terms

Reviews

Buying guide: Underfloor Heating

Underfloor heating warms a room from the floor up, using warm water pipes or electric heating elements laid beneath the floor finish. This category covers manifolds, control packs, connectors, system plates, edge insulation, thermostats and wiring centres for water systems, plus electric heating foil kits, insulation boards, membranes and cables.

Water or electric

A water (wet) system circulates warm water from a boiler or heat pump through loops of pipe, often 16mm, laid under the floor. Each loop connects to a manifold, and actuators on the manifold open and close the loops for each zone under the control of room thermostats and a wiring centre. An electric system heats foil, mats or cables directly from the electricity supply, controlled by its own thermostat. Pipes and elements can sit in a screed or on insulation boards and plates; follow the maker's guidance for your floor type.

Insulation and controls

In England, Approved Document L expects insulation under underfloor heating to limit heat lost downwards, with higher levels where the system runs intermittently or sits over an unheated space. Every underfloor heating system should have controls that adjust the operating temperature, and room thermostats for electric systems should have a manual override. New wet heating systems should be designed to run at a flow temperature of 55°C or lower where this is feasible.

Electrical safety

In England, installing a new electrical circuit, or adding to or altering a circuit in a room with a bath or shower, is notifiable under Part P of the Building Regulations. It must be done by a registered competent person or notified to building control. Check that your floor finish is suitable for use over underfloor heating.

For thermostats and timers, see heating controls, or browse pipe systems and fittings.

Shop all Underfloor Heating