Own Brand JET JCO10 System Protector 10L, Heating System Inhibitor, Central Heating Corrosion Protector, Boiler & Radiator Treatment

In stock
£248.14

Own Brand JET JCO10 System Protector 10L, Heating System Inhibitor, Central Heating Corrosion Protector, Boiler & Radiator Treatment

SKU W-P12989
Manufacturer part number
CH1-03-07550
EAN
5060106374554
£248.14
inc VAT£206.78 ex VAT
Lead time: 1-5 working days

Questions about this product? Chat with us

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Own Brand JET JCO10 System Protector 10L, Heating System Inhibitor, Central Heating Corrosion Protector, Boiler & Radiator Treatment (Part no. W-P12989)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

Product Overview

The Own Brand JET JCO10 System Protector 10L is a heating system protector designed to help defend sealed central heating systems from corrosion, scale build-up and sludge. It is used as an inhibitor treatment to support cleaner circulation, improved heat transfer and longer component life. Ideal for ongoing maintenance and protection after a system clean or flush.

Key Features

  • Helps reduce corrosion and scale – supports longer life for radiators, pipework and boiler components.
  • Sludge prevention support – helps keep systems cleaner for steadier heat output and efficiency.
  • Large 10L size – suitable for repeated servicing, maintenance teams, and larger properties.
  • Designed for sealed heating systems – ideal as a protector dose after a refill or system flush.

Use Case / Application

Suitable for use in domestic and light commercial central heating systems where inhibitor protection is required. Common applications include:

  • After draining down and refilling a sealed heating system
  • Following a powerflush or chemical clean to help maintain cleanliness
  • Routine boiler servicing and radiator maintenance programmes
  • Homes, flats, offices, small commercial units and landlord maintenance

Problem → Solution

Ideal for preventing rust, sludge and limescale that can cause cold spots on radiators, noisy boilers and reduced heating efficiency.

Product Specifications

• Manufacturer – Own Brand
• Manufacturer Part Number (MPN) – CH1-03-07550
• EAN / Barcode – 5060106374554
• Dimensions / Size – 10L
• Product Type – System Protector / Heating System Inhibitor
• Typical Applications / Use Cases – Sealed central heating systems; boiler and radiator protection; post-flush maintenance dosing

Why Buy from BHL

Own Brand products are selected to deliver dependable, practical performance for everyday installation and maintenance needs. Buy the Own Brand JET JCO10 System Protector 10L online from BHL for competitive pricing and free* & fast UK delivery. BHL are a specialist online merchant, trusted by thousands of satisfied customers online since 1998 with thousands of 5 star reviews, and your order is delivered with care from UK warehouses. Choose BHL for a smooth, reliable purchase of the correct part number CH1-03-07550.

*see our terms

Reviews

Buying guide: Central Heating Inhibitors

Central heating inhibitors are chemicals added to the water in a wet heating system to protect the boiler, radiators and pipes against corrosion and scale. Unchecked corrosion forms black magnetite sludge, which leads to cold spots and can damage the boiler. This category covers liquid inhibitors in bottles and drums, concentrates and gels, rapid-dose cans, fluid for solar thermal systems, and in-line scale inhibitors.

Choosing and dosing

Dose to the volume of water in the system; many inhibitors treat about 100 litres of system water per litre, so larger systems need more. Check the product suits every metal present, including aluminium. On open vented systems the inhibitor goes in through the feed and expansion cistern; on sealed systems it is injected at the filling point, and gels and rapid-dose cans can go in through a radiator bleed valve with an adaptor.

When to add and test it

Add inhibitor with the final fill of fresh water, after the system has been cleaned and flushed. In England, Approved Document L expects this before a new boiler is fitted, with the system prepared and commissioned to BS 7593. That code of practice also calls for the water to be tested at commissioning and every year, and for the inhibitor to be re-dosed every five years unless a laboratory test shows it is still working. Recheck the level after any work that drains down or dilutes the system.

Solar thermal circuits use their own inhibited glycol fluid, supplied ready to use; do not dilute it or mix it with other fluids. Follow the manufacturer's instructions and safety data. Work on the boiler's gas parts must only be carried out by a Gas Safe registered engineer.

Before dosing, see central heating cleaner, or protect the boiler further with central heating filters.

Shop all Central Heating Inhibitors