Searle (Kelvion) HTR DEF 800W 200V 2650mm Electric Defrost Heater Element, Replacement Heater Rod, Industrial Heating Element

In stock
£126.71

Searle (Kelvion) HTR DEF 800W 200V 2650mm Electric Defrost Heater Element, Replacement Heater Rod, Industrial Heating Element

SKU W-683264
Manufacturer part number
100461639
£126.71
inc VAT£105.59 ex VAT
Lead time: 1-5 working days

Questions about this product? Chat with us

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Searle (Kelvion) HTR DEF 800W 200V 2650mm Electric Defrost Heater Element, Replacement Heater Rod, Industrial Heating Element (Part no. W-683264)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

Product Overview

The Searle (Kelvion) HTR DEF is an electric defrost heater element rated at 800W and 200V with a 2650mm length, designed to support reliable defrost performance in refrigeration equipment. It helps reduce ice build-up and maintain efficient airflow and cooling. Ideal as a genuine-style replacement heater element to restore system performance and minimise downtime.

Key Features

  • 800W heating output – delivers consistent defrost heat to help prevent ice accumulation and maintain efficiency.
  • 200V electrical rating – suitable for compatible refrigeration and evaporator defrost circuits for safe, correct operation.
  • 2650mm length – designed for installations requiring a long heater rod for broad coverage across coils or trays.
  • Replacement-ready component – ideal for maintenance and repairs, helping reduce downtime and restore reliable defrost cycles.

Use Case / Application

Designed for use in refrigeration and cooling equipment where defrost heating is required, such as:

  • Cold rooms and walk-in fridges freezers
  • Commercial refrigeration cabinets and display cases
  • Evaporator coil defrost systems in food storage and processing areas
  • Industrial cooling installations and plant rooms

Suitable for service engineers and maintenance teams replacing a failed or underperforming defrost heater element.

Problem → Solution

Ideal for restoring proper defrost operation when ice build-up is restricting airflow, reducing cooling performance, or causing frequent system faults.

Product Specifications

Manufacturer – Searle (Kelvion)
Manufacturer Part Number (MPN) – 100461639
Dimensions / Size – 2650mm length
Product Type – Electric defrost heater element (heater rod)
Typical Applications / Use Cases – Refrigeration defrost systems, evaporator coil defrosting, commercial and industrial cooling equipment
Technical Specifications – 800W, 200V

About the Manufacturer & Buying from BHL

Searle (Kelvion) components are widely used in commercial and industrial refrigeration where dependable defrost performance matters. Choose this HTR DEF 800W 200V 2650mm heater element as a reliable replacement part to keep your system running efficiently. Order online from BHL, a specialist heating, plumbing and building supplies merchant trading online since 1998.

Reviews

Buying guide: Refrigeration

This category holds replacement parts for refrigeration and cooling equipment: hermetic, semi-hermetic and scroll compressors, condenser and evaporator fan motors, refrigerant oils, refrigerant cans and cylinders, adaptors, seals and fan controls.

Matching a compressor

  • Refrigerant: each compressor is built for particular refrigerants, such as R134a, R404A, R407C, R290 or R600a, so match the refrigerant already in the system.
  • Application range: compressors are rated LBP, MBP or HBP (low, medium or high back pressure) for the evaporating temperature they work at. LBP covers the coldest range, as in freezers, and HBP the warmest; check the range against what the system was designed for.
  • Electrical supply: check single phase 230V or three phase 400V, and the frequency; some models are wound for supplies outside the UK.
  • Capacity and connections: match the cooling capacity at the system's operating conditions, and choose a valved version if the system needs service valves.

Oils and refrigerants

Use the oil type and grade the compressor maker specifies. Synthetic polyolester (POE) oil is the usual choice for HFC refrigerants such as R134a, R404A and R407C. Hydrocarbon refrigerants such as R290 and R600a are flammable and need careful handling, so only technicians trained in the safe use of flammable refrigerants should open these systems.

Regulations

In Great Britain, anyone who installs, services or maintains, leak checks, recovers refrigerant from or decommissions stationary refrigeration, air conditioning or heat pump equipment containing F gas must hold the right F gas qualification, and the certificate category depends on the size of the system.

For valves, see valves; for copper pipe and fittings, see pipe systems and fittings.