Searle (Kelvion) TEC6 Fan Plate and Drain Pan, Replacement Drip Tray, Condensate Drain Pan, Cooler Spares

In stock
£205.01

Searle (Kelvion) TEC6 Fan Plate and Drain Pan, Replacement Drip Tray, Condensate Drain Pan, Cooler Spares

SKU W-650321
Manufacturer part number
100513754
£205.01
inc VAT£170.84 ex VAT
Lead time: 1-5 working days

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Searle (Kelvion) TEC6 Fan Plate and Drain Pan, Replacement Drip Tray, Condensate Drain Pan, Cooler Spares (Part no. W-650321)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

Product Overview

The Searle (Kelvion) TEC6 fan plate and drain pan is a genuine replacement component designed for TEC6 units, combining the fan plate area with a condensate collection tray. It helps channel moisture safely to the drain, reducing the risk of leaks, corrosion and water damage around electrical parts. Ideal for keeping your cooler or refrigeration equipment running cleanly and reliably.

Key Features

  • Designed for TEC6 compatibility – suitable for TEC6 units to support correct fit and dependable performance.
  • Condensate management – collects and directs water to the drain to help prevent drips, pooling and icing issues.
  • Protects surrounding components – helps reduce moisture exposure that can lead to corrosion or electrical faults.
  • Replacement part for maintenance – ideal for planned servicing or repair to minimise downtime and keep equipment compliant.
  • Robust component design – built for demanding refrigeration environments for longer service life.

Use Case / Application

Suitable for use in refrigeration and cooling equipment where TEC6 units are installed. Common applications include cold rooms, commercial kitchens, food preparation areas, supermarkets, warehouses, and plant rooms. Used during repair or routine servicing when an existing drain pan or fan plate is damaged, leaking, corroded or blocked, helping restore correct condensate drainage and safe operation.

Problem → Solution

Ideal for replacing a worn or leaking TEC6 condensate drip tray to stop water escaping the unit and help protect nearby electrics and surfaces.

Product Specifications

• Manufacturer – Searle (Kelvion)
• Manufacturer Part Number (MPN) – 100513754
• Product Type – Fan plate and drain pan (condensate drip tray) replacement part
• Typical Applications / Use Cases – TEC6 refrigeration and cooling equipment; cold rooms, commercial kitchens, retail refrigeration, plant rooms
• Technical Specifications – Compatible with TEC6 units

Why Buy from BHL?

Searle (Kelvion) is a trusted manufacturer of refrigeration components and spares, designed to keep cooling systems operating efficiently. Choose the Searle (Kelvion) TEC6 fan plate and drain pan (Part Number: 100513754) for a reliable, correct-fit replacement. Buy online from BHL for competitive pricing, genuine parts and free* fast UK delivery. BHL are a specialist online merchant, trusted by thousands of satisfied customers online since 1998 with thousands of 5 star reviews, with orders delivered with care from UK warehouses.

*see our terms

Reviews

Buying guide: Refrigeration

This category holds replacement parts for refrigeration and cooling equipment: hermetic, semi-hermetic and scroll compressors, condenser and evaporator fan motors, refrigerant oils, refrigerant cans and cylinders, adaptors, seals and fan controls.

Matching a compressor

  • Refrigerant: each compressor is built for particular refrigerants, such as R134a, R404A, R407C, R290 or R600a, so match the refrigerant already in the system.
  • Application range: compressors are rated LBP, MBP or HBP (low, medium or high back pressure) for the evaporating temperature they work at. LBP covers the coldest range, as in freezers, and HBP the warmest; check the range against what the system was designed for.
  • Electrical supply: check single phase 230V or three phase 400V, and the frequency; some models are wound for supplies outside the UK.
  • Capacity and connections: match the cooling capacity at the system's operating conditions, and choose a valved version if the system needs service valves.

Oils and refrigerants

Use the oil type and grade the compressor maker specifies. Synthetic polyolester (POE) oil is the usual choice for HFC refrigerants such as R134a, R404A and R407C. Hydrocarbon refrigerants such as R290 and R600a are flammable and need careful handling, so only technicians trained in the safe use of flammable refrigerants should open these systems.

Regulations

In Great Britain, anyone who installs, services or maintains, leak checks, recovers refrigerant from or decommissions stationary refrigeration, air conditioning or heat pump equipment containing F gas must hold the right F gas qualification, and the certificate category depends on the size of the system.

For valves, see valves; for copper pipe and fittings, see pipe systems and fittings.

Shop all Refrigeration