Searle (Kelvion) KM 175 Drain Pan Heater, Condensate Tray Heater, Defrost Heater, Refrigeration Drain Heater, Replacement Spare Part

In stock
£117.79

Searle (Kelvion) KM 175 Drain Pan Heater, Condensate Tray Heater, Defrost Heater, Refrigeration Drain Heater, Replacement Spare Part

SKU W-678008
Manufacturer part number
100461638
EAN
5051308001614
£117.79
inc VAT£98.16 ex VAT
Lead time: 1-5 working days

Questions about this product? Chat with us

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Searle (Kelvion) KM 175 Drain Pan Heater, Condensate Tray Heater, Defrost Heater, Refrigeration Drain Heater, Replacement Spare Part (Part no. W-678008)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

Product Overview

The Searle (Kelvion) KM 175 Drain Pan Heater is a replacement heater designed to warm the drain pan and help prevent condensate from freezing. Suitable for refrigeration and HVAC applications, it supports reliable drainage, helping reduce ice build-up, blockages and downtime.

Key Features

  • Purpose-built drain pan heating – helps keep condensate flowing to reduce freezing and overflow risks.
  • Replacement spare part – ideal for maintenance and repairs to restore correct operation quickly.
  • Supports defrost performance – assists with managing meltwater during defrost cycles for cleaner, safer drainage.
  • Genuine identification – supplied with matching manufacturer part number for accurate ordering and fewer compatibility issues.

Use Case / Application

Designed for use in refrigeration and cooling equipment where condensate collects in a drain tray or pan. Common applications include cold rooms, display cabinets, refrigerated cases, evaporator drain pans and other commercial cooling environments where ice build-up can cause blocked drains or water leaks.

Problem → Solution

Ideal for preventing frozen condensate and blocked drainage in refrigeration systems, helping maintain reliable operation and reducing service call-outs.

Product Specifications

  • Manufacturer – Searle (Kelvion)
  • Manufacturer Part Number (MPN) – 100461638
  • EAN / Barcode – 5051308001614
  • Product Type – Drain Pan Heater
  • Typical Applications / Use Cases – Refrigeration drain trays and pans, evaporator drain pans, cold room and commercial refrigeration condensate management

Buy from BHL

Searle (Kelvion) components are widely used in commercial refrigeration and cooling systems, trusted for dependable performance and serviceability. Order the Searle (Kelvion) KM 175 Drain Pan Heater (Part Number 100461638) from BHL for a straightforward, reliable replacement. Buy online today for competitive pricing, free* and fast UK delivery, and genuine parts delivered with care from UK warehouses. BHL are a specialist online merchant, trusted by thousands of satisfied customers online since 1998 with thousands of 5 star reviews.
*see our terms

Reviews

Buying guide: Refrigeration

This category holds replacement parts for refrigeration and cooling equipment: hermetic, semi-hermetic and scroll compressors, condenser and evaporator fan motors, refrigerant oils, refrigerant cans and cylinders, adaptors, seals and fan controls.

Matching a compressor

  • Refrigerant: each compressor is built for particular refrigerants, such as R134a, R404A, R407C, R290 or R600a, so match the refrigerant already in the system.
  • Application range: compressors are rated LBP, MBP or HBP (low, medium or high back pressure) for the evaporating temperature they work at. LBP covers the coldest range, as in freezers, and HBP the warmest; check the range against what the system was designed for.
  • Electrical supply: check single phase 230V or three phase 400V, and the frequency; some models are wound for supplies outside the UK.
  • Capacity and connections: match the cooling capacity at the system's operating conditions, and choose a valved version if the system needs service valves.

Oils and refrigerants

Use the oil type and grade the compressor maker specifies. Synthetic polyolester (POE) oil is the usual choice for HFC refrigerants such as R134a, R404A and R407C. Hydrocarbon refrigerants such as R290 and R600a are flammable and need careful handling, so only technicians trained in the safe use of flammable refrigerants should open these systems.

Regulations

In Great Britain, anyone who installs, services or maintains, leak checks, recovers refrigerant from or decommissions stationary refrigeration, air conditioning or heat pump equipment containing F gas must hold the right F gas qualification, and the certificate category depends on the size of the system.

For valves, see valves; for copper pipe and fittings, see pipe systems and fittings.

Shop all Refrigeration

Related products

Customers also bought