Gas fire spares: finding the right part for your fire

Ceramic fire coals, a copper thermocouple and small brass gas fire parts laid out on a workbench

To identify a gas fire spare, identify the appliance first, then check the specified manufacturer part number. Record the maker, full model name, serial number and GC number where available, and use the current manufacturer spares list for that appliance.

If you suspect a gas escape or carbon monoxide, stop. Do not operate electrical switches or use naked flames. Get everyone into fresh air. From outside, call the National Gas Emergency Service on 0800 111 999 for mains gas in Great Britain. In Northern Ireland, or for LPG, call the emergency number of the gas supplier shown on the bill, meter or tank, also from outside. Get urgent medical help for symptoms. Do not go back into the affected building until you have obtained advice. Keep the appliance out of use until a Gas Safe registered engineer has checked it.

Carbon monoxide is colourless, odourless and poisonous. Symptoms can include headache, dizziness, sickness, weakness, tiredness, confusion, chest or muscle pain, shortness of breath, flushing and loss of vision. Call NHS 111 if you think you might have symptoms. If you think someone has been exposed and they are finding it hard to breathe, have suddenly become confused, have lost consciousness, feel weak or have chest or muscle pain, call 999 or go to A&E. Do not drive to A&E: ask someone to drive or call 999 for an ambulance.

Do not select a thermocouple, pilot assembly, oxygen depletion sensor or ceramic fuel-effect set by appearance alone. Use a Gas Safe registered engineer for work on a gas fire, including diagnosis and replacement of gas-carrying or combustion-safety parts.

Start with the fire, not the faulty part

Two parts can look alike while having different connections, dimensions or operating characteristics. A familiar brand name such as Magiglo, Valor, Robinson Willey or Be Modern is therefore only the beginning of the identification process.

Look for the appliance data plate or identification label without dismantling the fire. Depending on the appliance, it may be accessible behind a removable decorative panel, near the controls or with the original instructions. If reaching it would require disturbing the appliance, leave that work to a Gas Safe registered engineer.

Record every identifier exactly as printed:

  • manufacturer or brand
  • complete model name and any model variant
  • serial number
  • GC number, where one is shown
  • fuel or gas information shown on the appliance
  • the number printed or stamped on the existing part

Take clear photographs of the complete data plate, the fire and the part in its installed position. These records give a supplier or engineer more useful information than a photograph of an unidentified loose component.

A GC number can help distinguish appliances with similar names, but it should be used alongside the model and manufacturer records. The earlier BHL guide, Boiler GC numbers: how to find yours and order the right spare part, covers finding a boiler GC number and ordering the right spare part.

Thermocouple, pilot or Oxypilot?

A thermocouple is associated with flame supervision on many gas appliances. It should not be treated as a generic item simply because its end fittings resemble those on the old component.

A pilot assembly can bring several elements together around the pilot flame. An Oxypilot is an oxygen-depletion pilot safety assembly that monitors the pilot flame. HSE says: "HSE strongly recommends the use of CO alarms as one useful precaution to give advance warning of CO in a property. Importantly alarms should not be regarded as a replacement for regular maintenance and safety checks by a Gas Safe registered engineer." Names used in conversations, old paperwork and listings are not always interchangeable, so the appliance documentation and exact part number should decide the match.

BHL lists the Dimplex Valor 540979 Oxypilot X-0540979. Its listed brand is Dimplex and its MPN is X-0540979.

Dimplex Valor 540979 Oxypilot
The Dimplex Valor 540979 Oxypilot.

The range also includes the Magiglo PF257 Pilot Assembly PIL0257. Its listed brand is Magiglo and its MPN is PIL0257.

Magiglo PF257 Pilot Assembly
The Magiglo PF257 Pilot Assembly.

Order these examples by their exact identifiers, not because another pilot looks similar. Confirm all details against the manufacturer's current data before ordering or fitting a part.

How to check a part number

Begin with the appliance manufacturer's current parts diagram, service information or spares list. Find the appliance by its complete identity, then locate the required component and compare the listed part number with the number offered by the supplier.

Keep leading zeroes, hyphens and letter prefixes when recording a number. X-0540979 and PIL0257, for example, are the MPNs for the linked Dimplex and Magiglo products respectively.

Older paperwork may show a number that has been replaced by a later reference. Do not assume that two numbers are equivalent unless the current manufacturer information establishes that relationship. If the records conflict, ask the manufacturer, supplier or attending engineer to resolve the identification before the part is ordered.

Model names can also cover several versions produced over time. A suffix, control type or serial-number range may affect the required component, even when the main model name is unchanged.

Coal sets and ceramic fuel effects

Ceramic coals and other fuel-effect pieces are part of the appliance's specified combustion arrangement, not loose decoration. Their shape, quantity and position can affect the flame pattern and combustion, so use only the specified set: fitting and arranging it is a job for a Gas Safe registered engineer, following the manufacturer's instructions.

Do not mix pieces from different sets or substitute a visually similar coal. Do not continue using broken, missing or incorrectly positioned pieces without advice from a Gas Safe registered engineer.

BHL lists the Dimplex Valor 5108037 Ceramic Coal Set. Its listed brand is Dimplex and its MPN is X-5108037.

Dimplex Valor 5108037 Ceramic Coal Set
The Dimplex Valor 5108037 Ceramic Coal Set.

The appliance instructions should provide the correct fuel-bed layout for the engineer. If those instructions are missing, ask the engineer to obtain the right edition for the exact model rather than copying the arrangement from another fire or an online photograph.

What to give the engineer or supplier

A short, complete record reduces the chance of confusing similar appliances. Send the information as text as well as photographs, because faint characters on a label may be difficult to read from an image.

Include the full appliance identity, all numbers on the data plate, the existing component number, a description of the reported symptom and photographs taken before anything is removed. The symptom helps a Gas Safe registered engineer diagnose the fault, but it does not identify the required part by itself.

Keep removed components available for comparison unless the engineer advises otherwise. Packaging, invoices and previous service records may also preserve a useful manufacturer reference.

For gas work, use the HSE domestic gas safety information and check the engineer's registration and relevant categories of work. The Gas Safety (Installation and Use) Regulations 1998 may also be relevant, so check the current text and applicable official guidance rather than relying on a summary.

Mistakes that lead to the wrong spare

  • Matching by appearance: similar-looking pilots and thermocouples are not automatically interchangeable.
  • Using only the brand: a manufacturer may have produced many models and variants.
  • Dropping part-number characters: prefixes, suffixes, zeroes and hyphens can matter.
  • Assuming an old number has a current equivalent: confirm any supersession in manufacturer information.
  • Copying a coal layout: the engineer should follow the instructions for the exact appliance and fuel-effect set.
  • Ordering before diagnosis: ignition or flame problems can have more than one cause.

Do not attempt to prove a diagnosis by bypassing a safety device, altering a pilot or running the fire with its fuel effect incorrectly arranged. Turn the appliance off if its safe operation is in doubt and seek advice from a Gas Safe registered engineer.

Frequently asked questions

Can a gas fire thermocouple be chosen by length?

No. Length alone does not establish the correct part. Use the fire's exact identity and the manufacturer part number, then have a Gas Safe registered engineer confirm the diagnosis and replacement.

Where can I find my gas fire model number?

Check the accessible appliance data plate, identification label, instructions and original paperwork. Do not dismantle the fire to reach a label.

Can I replace one damaged ceramic coal?

Order only the replacement pieces or complete set specified by the appliance manufacturer, and have a Gas Safe registered engineer fit and arrange them. The correct answer depends on the exact model and its current manufacturer instructions.

Can I fit a pilot assembly myself?

Use a Gas Safe registered engineer for diagnosis and replacement of a gas fire pilot assembly. This article is intended to help identify a part, not to provide fitting instructions.

What if the manufacturer no longer lists my model?

Gather the model, serial number, GC number, existing part number and photographs, then ask a Gas Safe registered engineer or specialist supplier to check authoritative records. Do not substitute a similar-looking component.

Parts and products at BHL

BHL lists the linked Dimplex Oxypilot, Dimplex ceramic coal set and Magiglo pilot assembly alongside the wider Fires, Stoves & Accessories collection. The Boiler Spares collection covers a separate group of heating-appliance parts.

Before ordering, compare the complete appliance identity and manufacturer part number with current manufacturer records. For any gas-fire diagnosis, servicing or fitting work, use a Gas Safe registered engineer.