Own Brand JET JCO10 System Protector 20L, Heating System Inhibitor, Central Heating Corrosion Protector, Radiator & Boiler Treatment Fluid

In stock
£509.82

Own Brand JET JCO10 System Protector 20L, Heating System Inhibitor, Central Heating Corrosion Protector, Radiator & Boiler Treatment Fluid

SKU W-P12990
Manufacturer part number
CH1-03-07551
EAN
5060106374561
£509.82
inc VAT£424.85 ex VAT
Lead time: 1-5 working days

Questions about this product? Chat with us

Price Beater

Found this item cheaper elsewhere? Tell us where and our team will see if we can beat the price you've seen.

Product: Own Brand JET JCO10 System Protector 20L, Heating System Inhibitor, Central Heating Corrosion Protector, Radiator & Boiler Treatment Fluid (Part no. W-P12990)

UK or international, for example 01234 567890 or +44 1234 567890

If you leave out https:// we add it for you.

Questions about this part? Talk to our team

Phone: 01226 369637

Opening times

Monday to Friday 08:00 to 17:00
Saturday and Sunday: closed

Delivery

Free standard delivery on orders over £100 ex VAT. Orders below this carry a £7.95 inc VAT delivery charge. Express delivery items £19.95 inc VAT, allow 1 to 2 working days. Delivery details and surcharges

Need delivery on or before a specific day? Ask our team.

Description

Product Overview

Own Brand JET JCO10 System Protector is a 20L treatment fluid designed for protecting wet central heating systems. It helps reduce corrosion and the build-up of sludge, supporting better system efficiency and reliability. Suitable for maintaining boilers, radiators and pipework in good working order.

Key Features

  • 20L bulk container – ideal for larger properties or trade use with fewer changeovers and less downtime.
  • System protection treatment – helps minimise corrosion and internal wear to extend the working life of your heating system.
  • Supports cleaner circulation – helps reduce sludge formation for improved heat transfer and more consistent radiator performance.
  • Designed for wet central heating systems – a practical choice for routine maintenance and ongoing system care.

Use Case / Application

Designed for use in sealed or open-vented wet central heating systems where ongoing protection is required. Common applications include:

  • Domestic heating systems in houses and flats
  • Light commercial buildings and small offices
  • Routine servicing after a drain down and refill
  • System maintenance to help protect boilers, radiators and circulating pipework

Problem to Solution

Ideal for helping prevent corrosion and sludge that can reduce heat output, cause cold spots on radiators and shorten system lifespan.

Product Specifications

• Manufacturer – Own Brand
• Manufacturer Part Number (MPN) – CH1-03-07551
• EAN / Barcode – 5060106374561
• Dimensions / Size – 20L
• Product Type – System Protector

Why Buy from BHL

Own Brand products are selected to deliver dependable performance for everyday maintenance and repair work, including the JET JCO10 System Protector 20L for protecting wet central heating systems. Buy online today from BHL for competitive pricing and free* & fast UK delivery. BHL are a specialist online merchant, trusted by thousands of satisfied customers online since 1998 with thousands of 5 star reviews. Your order is dispatched from UK warehouses and delivered with care. *see our terms

Reviews

Buying guide: Central Heating Inhibitors

Central heating inhibitors are chemicals added to the water in a wet heating system to protect the boiler, radiators and pipes against corrosion and scale. Unchecked corrosion forms black magnetite sludge, which leads to cold spots and can damage the boiler. This category covers liquid inhibitors in bottles and drums, concentrates and gels, rapid-dose cans, fluid for solar thermal systems, and in-line scale inhibitors.

Choosing and dosing

Dose to the volume of water in the system; many inhibitors treat about 100 litres of system water per litre, so larger systems need more. Check the product suits every metal present, including aluminium. On open vented systems the inhibitor goes in through the feed and expansion cistern; on sealed systems it is injected at the filling point, and gels and rapid-dose cans can go in through a radiator bleed valve with an adaptor.

When to add and test it

Add inhibitor with the final fill of fresh water, after the system has been cleaned and flushed. In England, Approved Document L expects this before a new boiler is fitted, with the system prepared and commissioned to BS 7593. That code of practice also calls for the water to be tested at commissioning and every year, and for the inhibitor to be re-dosed every five years unless a laboratory test shows it is still working. Recheck the level after any work that drains down or dilutes the system.

Solar thermal circuits use their own inhibited glycol fluid, supplied ready to use; do not dilute it or mix it with other fluids. Follow the manufacturer's instructions and safety data. Work on the boiler's gas parts must only be carried out by a Gas Safe registered engineer.

Before dosing, see central heating cleaner, or protect the boiler further with central heating filters.

Shop all Central Heating Inhibitors

Related products

Customers also bought